Impact of limited treadmill exercise on adenosine Tc-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging in coronary artery disease

Am J Cardiol. 1999 Aug 15;84(4):400-3. doi: 10.1016/s0002-9149(99)00323-9.

Abstract

Limited exercise combined with dipyridamole increases myocardial perfusion defect severity compared with dipyridamole alone. The impact of limited exercise combined with adenosine on myocardial perfusion defect severity is unknown. This study compares myocardial perfusion defect severity with adenosine alone and adenosine combined with limited exercise. Thirty-two patients with coronary artery disease underwent on separate days and in randomized order technetium-99m sestamibi (25 to 30 mCi) single-photon emission computed tomographic imaging at rest, after adenosine (140 microg/kg/min x 6 minutes), and after adenosine (140 microg/kg/min x 4 minutes) during 6 minutes of modified Bruce treadmill exercise (adenosine-exercise). Radiopharmaceutical was injected at 3 and 5 minutes during adenosine and adenosine-exercise, respectively. Images were interpreted by a consensus agreement of 3 nuclear cardiologists without knowledge of patient identity, stress protocol, or clinical data using a 17-segment model and 5-point scoring system. A summed stress score (SSS), summed rest score (SRS), and summed difference (SSS-SRS) score (SDS) were calculated for each image. Peak stress heart rate and rate-pressure product were higher for adenosine-exercise than adenosine (102 +/- 19 vs 81 +/- 11 beats/min and 13,972 +/- 4,265 vs 10,623 +/- 2,131, respectively; both p <0.001). Sensitivity for detection of > or = 50% coronary stenosis was 75% and 72% for adenosine-exercise and adenosine, respectively (p = NS). There were no differences in SSS and SDS between adenosine-exercise and adenosine (8.2 +/- 5.9 vs 8.1 +/- 6.3 and 4.9 +/- 4.1 vs 5.2 +/- 4.6, respectively; both p = NS). Thus, in patients with coronary artery disease, limited treadmill exercise combined with adenosine does not increase myocardial perfusion defect severity compared with standard adenosine technetium-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenosine* / administration & dosage
  • Adult
  • Aged
  • Aged, 80 and over
  • Blood Pressure
  • Coronary Circulation / physiology*
  • Coronary Disease / diagnostic imaging*
  • Coronary Disease / physiopathology
  • Electrocardiography
  • Exercise Test
  • Exercise*
  • Female
  • Heart / diagnostic imaging*
  • Heart Rate
  • Humans
  • Injections, Intravenous
  • Male
  • Middle Aged
  • Prognosis
  • Prospective Studies
  • Radiopharmaceuticals* / administration & dosage
  • Severity of Illness Index
  • Technetium Tc 99m Sestamibi* / administration & dosage
  • Tomography, Emission-Computed, Single-Photon / methods*

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sestamibi
  • Adenosine