85Kr measurement system for continuous monitoring at the Meteorological Research Institute, Japan

J Environ Monit. 2001 Dec;3(6):688-96. doi: 10.1039/b105067m.

Abstract

A 85Kr measurement system for continuous monitoring based principally on the BfS-IAR method (activity measurement of 85Kr by gas counting coupled with gas chromatographic separation, using pure CH4 as carrier and Counting gas) was implemented for the first time in Japan. In this paper, a detailed description of the system and procedures is given and the inter-comparison results of our system with the BfS-IAR system are presented. A consistent temporal concentration change with high accuracy and consistency of the respective data with the BfS-IAR data (maximum difference of 5%) were achieved with the Meteorological Research Institute (MRI) system, which shows that the system is valid and reliable for the purpose of background monitoring for 85Kr in air. Also, the 85Kr monitoring record at the MRI during 1995-2001 is described. The record distinctively shows the Northern Hemispheric background 85Kr concentrations at the mid-latitude and the elevated concentrations affected by the operation of a nuclear fuel reprocessing plant in Tokai-mura, Ibaraki. Japan.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Air Pollutants, Radioactive / analysis*
  • Chromatography, Gas
  • Environmental Monitoring*
  • Japan
  • Krypton Radioisotopes / analysis*

Substances

  • Air Pollutants, Radioactive
  • Krypton Radioisotopes