Myocardial delayed enhancement imaging using inversion recovery single-shot steady-state free precession: initial experience

J Magn Reson Imaging. 2004 Aug;20(2):327-30. doi: 10.1002/jmri.20095.

Abstract

Purpose: To evaluate the feasibility of using an inversion recovery single-shot steady-state free precession (SS_SSFP) sequence for myocardial delayed enhancement (MDE) imaging, and to compare SS_SSFP with the conventional inversion recovery segmented fast gradient echo (IR_FGRE) technique.

Materials and methods: Ten subjects (four volunteers and six patients with suspected or known coronary disease) were included in this study. All subjects were scanned with both IR_FGRE and SS_SSFP sequences 15-25 minutes after gadopentetate dimeglumine injection. Overall image quality, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) between the two techniques were compared.

Results: Compared to IR_FGRE, SS_SSFP exhibited adequate image quality (average scores = 3.8 for IR_FGRE and 3.9 for SS_SSFP) with much shorter acquisition time (14.4 seconds for IR_FGRE and 1.3 seconds for SS_SSFP). SS_SSFP images showed higher SNRs (P < 0.05) and less motion artifact from breathing. Enhanced myocardium was detected by both techniques in three patients, but the image sharpness is compromised in SS_SSFP images.

Conclusion: SS_SSFP provides adequate image quality compared to IR_FGRE, while requiring a much shorter acquisition time. It is feasible to use SS_SSFP as an alternative method for MDE imaging, especially in patients who have difficulty with holding their breath.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Aged
  • Coronary Disease / diagnosis*
  • Feasibility Studies
  • Female
  • Humans
  • Image Processing, Computer-Assisted*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Myocardium / pathology