Crossover behavior in burst avalanches: signature of imminent failure

Phys Rev Lett. 2005 Sep 16;95(12):125501. doi: 10.1103/PhysRevLett.95.125501. Epub 2005 Sep 12.

Abstract

The statistics of damage avalanches during a failure process typically follows a power law. When these avalanches are recorded only near the point at which the system fails catastrophically, one finds that the power law has an exponent which is different from that one finds if the recording of events starts away from the vicinity of catastrophic failure. We demonstrate this analytically for bundles of many fibers, with statistically distributed breakdown thresholds for the individual fibers and where the load is uniformly distributed among the surviving fibers. In this case the distribution D(Delta) of the avalanches (Delta) follows the power law Delta-xi with xi=3/2 near catastrophic failure and xi=5/2 away from it. We also study numerically square networks of electrical fuses and find xi=2.0 near catastrophic failure and xi=3.0 away from it. We propose that this crossover in xi may be used as a signal of imminent failure.