Clinical impact of fluorine-18 fluorodeoxyglucose positron emission tomography in cancer patients. A comparative study between dedicated camera and dual-head coincidence gamma camera

Q J Nucl Med Mol Imaging. 2006 Mar;50(1):68-77.

Abstract

Aim: Positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) can be performed using a dedicated PET scanner (PET-I) or a dual-head coincidence gamma camera (CGC-I). The aim of this study was to comparatively assess the impact of PET-I and CGC-I on clinical management in cancer patients.

Methods: From November 2000 to November 2002, PET-I and CGC-I were performed at an interval of 2 days in 151 patients with colorectal cancer (n=40), breast cancer (n=28), thyroid cancer (n=23), lung tumors (n=22), germ cell tumors (n=14), unknown primary cancer (n=7) and other cancers (n=17). PET-I and CGC-I were interpreted independently with knowledge of conventional imaging (CI). In June 2003, theoretical management, e.g. treatment modality/ies and treatment intent (curative or palliative), after CI, PET-I and CGC-I were stated during multidisciplinary sessions and were a posteriori considered as appropriate or inappropriate using pathological and follow-up data.

Results: The theoretical management proposed after PET-I and after CGC-I was similar in 112/151 (74%; 95% CI: 66-81%) patients. In 125 assessable patients, theoretical management after PET-I was appropriate in 86% (95% CI: 79-92%), significantly higher (P=0.0033) than after CGC-I (70%; 95% CI: 62-78%). Both proportions were also higher than after CI (46%; 95% CI: 37-56%), (P<0.0001). A similar trend for higher proportions of appropriate management after PET-I than after CGC-I was observed for each tumor localization.

Conclusions: The clinical impact of PET-I is superior to that of CGC-I in a large series of cancer patients. Although CGC-I could be considered as an acceptable alternative, PET-I remains the standard and should preferably equip nuclear medicine departments.

Publication types

  • Comparative Study
  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Equipment Design
  • Equipment Failure Analysis
  • Female
  • Fluorodeoxyglucose F18*
  • France / epidemiology
  • Gamma Cameras / statistics & numerical data*
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Neoplasms / diagnostic imaging*
  • Neoplasms / epidemiology*
  • Positron-Emission Tomography / instrumentation*
  • Positron-Emission Tomography / statistics & numerical data*
  • Practice Patterns, Physicians' / statistics & numerical data*
  • Prognosis
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18