Quality control of radiotherapy during pelvic irradiation

Radiother Oncol. 1991 Mar;20(3):203-6. doi: 10.1016/0167-8140(91)90098-2.

Abstract

For 20 patients undergoing pelvic irradiation, various set-up methods were compared for accuracy of field placement. The overall incidence of errors on 294 fields checked was lower (p less than 0.001) than that in a previous study. A standard deviation of 1.5 mm for lateral placement accuracy was obtained.

Publication types

  • Clinical Trial
  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carcinoma / radiotherapy*
  • Female
  • Humans
  • Pelvis
  • Quality Assurance, Health Care*
  • Radiotherapy Planning, Computer-Assisted*
  • Uterine Cervical Neoplasms / radiotherapy*
  • Uterine Neoplasms / radiotherapy*