Poor predictive value of intraoperative real-time dosimetry for prostate seed brachytherapy

Int J Radiat Oncol Biol Phys. 2008 Oct 1;72(2):605-9. doi: 10.1016/j.ijrobp.2008.06.1484.

Abstract

Purpose: To identify dosimetric parameters predictive of a good prostate seed I(125) quality implant. We analyzed preimplant and postimplant realtime dosimetry in patients treated with intraoperative (IO) inverse planning.

Methods and materials: We analyzed 127 consecutively treated patients with primarily low-risk prostate carcinoma who underwent prostate permanent seed I(125) brachytherapy using an IO planning approach. The implant was done using the three-dimensional transrectal ultrasound (PRE-TRUS)-guided IO interactive inverse preplanning system. The TRUS was repeated in the operating room after the implant procedure was complete (POST-TRUS). The prostate was recontoured and postimplant dosimetry was calculated. Each patient underwent computed tomography scan on Day 28 (CT-D28) to evaluate implant quality. Area under the receiver operating characteristic curves (AUROC) was evaluated for models predictive of a V100 of > or =90% and a D90 of > or =140 Gy on the basis of CT-D28 values.

Results: On CT-D28, 72.4% of patients had a V100 of > or =90% and 74.8% had a D90 of > or =140 Gy. AUROC for a V100 of > or =90% was 0.665 (p = 0.004) on PRE-TRUS and 0.619 (p = 0.039) on POST-TRUS. AUROC for D90 of > or =140 Gy was 0.602 (p = 0.086) on PRE-TRUS and 0.614 (p = 0.054) on POST-TRUS. Using PRE-TRUS V100 cutoff of >97% gives sensitivity of 88% and a false-positive rate of 63%. A POST-TRUS D90 cutoff of >170 Gy resulted in a sensitivity of 62% and a false-positive rate of 34%.

Conclusions: Because of unacceptably high false-positive rates, IO preimplant and postimplant TRUS-based dosimetry are not accurate tools to predict for postimplant computed tomography-based dosimetry.

MeSH terms

  • Aged
  • Area Under Curve
  • Brachytherapy / instrumentation*
  • False Positive Reactions
  • Humans
  • Imaging, Three-Dimensional
  • Iodine Radioisotopes / therapeutic use
  • Male
  • Middle Aged
  • Prostate-Specific Antigen / blood
  • Prostatic Neoplasms / blood
  • Prostatic Neoplasms / diagnostic imaging
  • Prostatic Neoplasms / radiotherapy*
  • Radiometry
  • Radiotherapy Dosage
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed
  • Ultrasonography, Interventional / methods

Substances

  • Iodine Radioisotopes
  • Prostate-Specific Antigen