The use of tapered self-expanding stents and embolic protection devices in the treatment of stenotic ectatic coronary arteries: a report of two cases

Catheter Cardiovasc Interv. 2008 Nov 1;72(5):643-6. doi: 10.1002/ccd.21740.

Abstract

Objective: The usage of tapered self-expanding stents and embolic protection devices in the treatment of stenotic ectatic coronary arteries.

Background: Coronary artery ectasia (CAE) is an uncommon disease that is occasionally found during cardiac catheterization. A high incidence of artherosclerotic disease is associated with CAE. Currently, there is no evidence-based approach for the management of stenotic ectatic coronary arteries (SEC).

Methods: Percutaneous intervention with carotid stenting system and embolic protection system to recanalize SEC.

Results: We describe two patients who presented with acute coronary syndrome and were found to have CAE with significant stenosis. Both patients underwent percutaneous intervention with RX ACCULINK Carotid stenting system and ACCUNET embolic protection system (Abbott Laboratories, Abbott Park, IL), successfully. This carotid stenting system is approved by FDA for stenting of extracranial carotid artery stenosis.

Conclusion: To the best of our knowledge, this is the first case report illustrating the usage of these devices as an alternative for the treatment of SEC.

Publication types

  • Case Reports

MeSH terms

  • Acute Coronary Syndrome / diagnostic imaging
  • Acute Coronary Syndrome / etiology
  • Acute Coronary Syndrome / therapy*
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Coronary Aneurysm / complications
  • Coronary Aneurysm / diagnostic imaging
  • Coronary Aneurysm / therapy*
  • Coronary Angiography
  • Coronary Stenosis / complications
  • Coronary Stenosis / diagnostic imaging
  • Coronary Stenosis / therapy*
  • Dilatation, Pathologic
  • Embolism / etiology
  • Embolism / prevention & control*
  • Equipment Design
  • Filtration / instrumentation*
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design
  • Stents*