Sulfonium ion derivatization, isobaric stable isotope labeling and data dependent CID- and ETD-MS/MS for enhanced phosphopeptide quantitation, identification and phosphorylation site characterization

J Am Soc Mass Spectrom. 2012 Apr;23(4):577-93. doi: 10.1007/s13361-011-0190-0. Epub 2011 Jul 6.

Abstract

An amine specific peptide derivatization strategy involving the use of novel isobaric stable isotope encoded 'fixed charge' sulfonium ion reagents, coupled with an analysis strategy employing capillary HPLC, ESI-MS, and automated data dependent ion trap CID-MS/MS, -MS(3), and/or ETD-MS/MS, has been developed for the improved quantitative analysis of protein phosphorylation, and for identification and characterization of their site(s) of modification. Derivatization of 50 synthetic phosphopeptides with S,S'-dimethylthiobutanoylhydroxysuccinimide ester iodide (DMBNHS), followed by analysis using capillary HPLC-ESI-MS, yielded an average 2.5-fold increase in ionization efficiencies and a significant increase in the presence and/or abundance of higher charge state precursor ions compared to the non-derivatized phosphopeptides. Notably, 44% of the phosphopeptides (22 of 50) in their underivatized states yielded precursor ions whose maximum charge states corresponded to +2, while only 8% (4 of 50) remained at this maximum charge state following DMBNHS derivatization. Quantitative analysis was achieved by measuring the abundances of the diagnostic product ions corresponding to the neutral losses of 'light' (S(CH(3))(2)) and 'heavy' (S(CD(3))(2)) dimethylsulfide exclusively formed upon CID-MS/MS of isobaric stable isotope labeled forms of the DMBNHS derivatized phosphopeptides. Under these conditions, the phosphate group stayed intact. Access for a greater number of peptides to provide enhanced phosphopeptide sequence identification and phosphorylation site characterization was achieved via automated data-dependent CID-MS(3) or ETD-MS/MS analysis due to the formation of the higher charge state precursor ions. Importantly, improved sequence coverage was observed using ETD-MS/MS following introduction of the sulfonium ion fixed charge, but with no detrimental effects on ETD fragmentation efficiency.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Amino Acid Sequence
  • Chromatography, High Pressure Liquid / methods
  • Ions / chemistry
  • Isotope Labeling / methods*
  • Molecular Sequence Data
  • Phosphopeptides / analysis*
  • Phosphopeptides / chemistry*
  • Phosphorylation
  • Succinimides / chemistry
  • Sulfonium Compounds / chemistry*
  • Tandem Mass Spectrometry / methods*

Substances

  • Ions
  • Phosphopeptides
  • Succinimides
  • Sulfonium Compounds