Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects

Invest Ophthalmol Vis Sci. 2011 Dec 20;52(13):9629-35. doi: 10.1167/iovs.11-7481.

Abstract

Purpose: To evaluate the ocular and systemic factors influencing measurements of optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thickness with spectral-domain optical coherence tomography (SD-OCT) in healthy Chinese adults.

Methods: Adults ranging in age from 40 to 80 years were consecutively recruited from the population-based Singapore Chinese Eye Study. A SD-OCT instrument was used to measure ONH and RNFL parameters. A total of 542 eyes from 542 non-glaucomatous Chinese subjects were analyzed. Univariable and multiple linear regression analyses were performed to examine the effects of a range of ocular (e.g., intraocular pressure [IOP], axial length [AL], disc area) and systemic (e.g., blood pressure, serum glucose) factors on ONH and RNFL parameters.

Results: In multiple regression analyses, neuroretinal rim area was independently associated with age (β = -0.006, P < 0.001), disc area (β = 0.183, P < 0.001), IOP (β = -0.009, P = 0.008), AL (β = -0.023, P = 0.004), and lens nuclear color (β = 0.042, P = 0.001). Vertical cup-to-disc ratio was independently correlated with age (β = 0.003, P < 0.001), disc area (β = 0.207, P < 0.001), IOP (β = 0.004, P = 0.014), AL (β = 0.010, P = 0.008), and lens nuclear color (β = -0.017, P = 0.006). Average RNFL thickness was independently related to age (β = -0.204, P = 0.001), disc area (β = 4.218, P < 0.001), signal strength (β = 1.348, P < 0.001), and AL (β = -1.332, P < 0.001). Disc area had the strongest effect on measurements of ONH parameters and RNFL thickness.

Conclusions: In a non-glaucomatous population, optic nerve measurements with SD-OCT vary with disc area, age, IOP, AL, lens nuclear color, and signal strength, but systemic parameters have little influence. This information may be useful for interpretation of SD-OCT measurements.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Aging / physiology
  • Asian People
  • Axial Length, Eye / anatomy & histology
  • Blood Pressure / physiology
  • Female
  • Humans
  • Intraocular Pressure / physiology
  • Male
  • Middle Aged
  • Nerve Fibers*
  • Optic Disk / anatomy & histology*
  • Optic Nerve / anatomy & histology*
  • Reference Values
  • Retinal Ganglion Cells / cytology*
  • Singapore / epidemiology
  • Tomography, Optical Coherence*