Optoelectronic plethysmography demonstrates abrogation of regional chest wall motion dysfunction in patients with pectus excavatum after Nuss repair

J Pediatr Surg. 2012 Jan;47(1):160-4. doi: 10.1016/j.jpedsurg.2011.10.038.

Abstract

Purpose: We previously demonstrated that patients with pectus excavatum (PE) have significantly decreased chest wall motion at the pectus defect compared with the rest of the chest vs unaffected individuals and use abdominal respiratory contributions to compensate for decreased upper chest wall motion. We hypothesize that PE repair will reverse chest wall motion dysfunction.

Methods: A prospective, institutional review board-approved study compared patients with PE before and after Nuss repair. Informed consent was obtained before motion analysis. Sixty-four patients with uncorrected PE ages 10 to 21 years underwent optoelectronic plethysmography analysis. Repeat analysis was performed in 42 patients 6 months postoperative (PO).

Results: Volume of the chest wall and its subdivisions were calculated. Total chest wall volume at rest was significantly increased after repair and in each thoracic compartment. PO patients developed increased midline marker excursion at the pectus defect and significantly decreased excursion at the level of the umbilicus.

Conclusions: Optoelectronic plethysmography kinematic analysis demonstrates that chest wall remodeling during Nuss repair results in increased thoracic volume. Chest wall motion dysfunction at the pectus defect is reversed after Nuss repair. Abdominal respiratory contributions are also markedly decreased. These findings may help to explain why patients with PE report an improvement in endurance after the Nuss procedure.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Electronics, Medical
  • Female
  • Funnel Chest / physiopathology*
  • Funnel Chest / surgery*
  • Humans
  • Male
  • Optical Phenomena
  • Plethysmography / methods
  • Prospective Studies
  • Thoracic Wall / physiopathology*