High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction

Gastrointest Endosc. 2012 Feb;75(2):310-8. doi: 10.1016/j.gie.2011.09.043.

Abstract

Background: EUS-guided liver biopsy by Trucut yields variable specimen adequacy at high cost, limiting its utility. A modified EUS-guided technique with reliable adequacy could be a viable alternative to standard techniques in cost-effective clinical settings.

Objective: To describe our experience with EUS-guided liver biopsy by 19-gauge FNA, non-Trucut, needle in a cost-effective setting: patients with abnormal liver test results of unclear etiology referred for EUS to exclude biliary obstruction in whom an unrevealing EUS would have prompted a next-step liver biopsy by the referring physician.

Design: Prospective case series.

Setting: Tertiary-care teaching hospital.

Patients: Consecutive patients with abnormal liver tests referred for EUS.

Interventions: EUS-guided liver biopsy by 19-gauge FNA needle (non-Trucut).

Main outcome measurements: Diagnostic yield, specimen adequacy, and complications. An adequate specimen was defined as a length of 15 mm or longer and 6 or more complete portal tracts (CPTs).

Results: Between July 2008 and July 2011, 22 of 31 consecutive patients meeting inclusion criteria underwent unrevealing EUS with same-session EUS-guided liver biopsy by 19-gauge FNA needle. A median of 2 FNA passes (range 1-3) yielded a median specimen length of 36.9 mm (range 2-184.6 mm) with a median of 9 CPTs (range 1-73 CPTs). EUS-guided liver biopsies yielded a histologic diagnosis and adequate specimens in 20 of 22 patients (91%). Expanded experience led to improved specimen adequacy. There were no complications.

Limitation: Small study size.

Conclusions: EUS-guided liver biopsy by using a 19-gauge FNA needle appears to be feasible and safe and provides excellent diagnostic yield and specimen adequacy.

Publication types

  • Clinical Trial

MeSH terms

  • Adult
  • Aged
  • Biopsy, Fine-Needle / adverse effects
  • Biopsy, Fine-Needle / instrumentation
  • Biopsy, Fine-Needle / methods*
  • Cholestasis / complications
  • Cholestasis / diagnostic imaging
  • Cholestasis / pathology*
  • Endosonography
  • Female
  • Humans
  • Liver Diseases / diagnostic imaging
  • Liver Diseases / etiology
  • Liver Diseases / pathology*
  • Liver Function Tests
  • Male
  • Middle Aged
  • Prospective Studies
  • Ultrasonography, Interventional* / adverse effects