An ultrasound study of cerebral venous drainage after internal jugular vein catheterization

Crit Care Res Pract. 2012:2012:685481. doi: 10.1155/2012/685481. Epub 2012 May 17.

Abstract

Objectives. It has been advocated that internal jugular vein (IJV) cannulation in patients at risk for intracranial hypertension could impair cerebral venous return. Aim of this study was to demonstrate that ultrasound-guided IJV cannulation in elective neurosurgical patients is safe and does not impair cerebral venous return. Methods. IJV cross-sectional diameter and flow were measured using two-dimensional ultrasound and Doppler function bilaterally before and after IJV cannulation with the head supine and elevated at 30°. Results. Fifty patients with intracranial lesions at risk for intracranial hypertension were enrolled in this observational prospective study. IJV diameters before and after ultrasound-guided cannulation were not statistically different during supine or head-up position and the absolute variation of the venous flow revealed an average reduction of the venous flow after cannulation without a significant reduction of the venous flow rate after cannulation. Conclusions. Ultrasound-guided IJV cannulation in neurosurgical patients at risk for intracranial hypertension does not impair significantly jugular venous flow and indirectly cerebral venous return.