The accuracy of ultrasound volume flow measurements in the complex flow setting of a forearm vascular access

J Vasc Access. 2013 Jul-Sep;14(3):281-90. doi: 10.5301/jva.5000118. Epub 2012 Nov 16.

Abstract

Purpose: Maturation of an arterio-venous fistula (AVF) frequently fails, with low post-operative fistula flow as a prognostic marker for this event. As pulsed wave Doppler (PWD) is commonly used to assess volume flow, we studied the accuracy of this measurement in the setting of a radio-cephalic AVF.

Methods: As in-vivo validation of fistula flow measurements is cumbersome, we performed simulations, integrating computational fluid dynamics with an ultrasound (US) simulator. Flow in the arm was calculated, based on a patient-specific model of the arm vasculature pre and post AVF creation. Raw ultrasound signals were subsequently simulated, from which Doppler spectra were calculated in both a proximal and a distal location.

Results: The velocity component in the direction of the PWD-US beam (vPWD), in a centered, small, sample volume, can be captured accurately using PWD spectrum mean-tracking (maximum bias [mB] 8.1%). However, when deriving flow rate from these measurements, a high degree of inaccuracy occurs. First, the angle-correction of vPWD towards the velocity along the axis of the vessel is largely influenced by the radial velocity components in the complex flow field (mB=16.3%). Second, the largest error is introduced when transferring the centerline velocity to the cross-sectional mean velocity without any knowledge of the flow profile (mB=97.7%).

Conclusions: In the setting of a forearm AVF, flow estimates based on PWD are hampered by the complex flow patterns. Overall, flow estimation based on centerline measurement, analyzed by mean-tracking of the RF-spectral estimates, under the assumption of a parabolic flow profile, appeared to provide the most reasonable values.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arteriovenous Shunt, Surgical*
  • Blood Flow Velocity
  • Brachiocephalic Veins / diagnostic imaging*
  • Brachiocephalic Veins / physiopathology
  • Brachiocephalic Veins / surgery*
  • Computer Simulation
  • Echocardiography, Doppler, Pulsed*
  • Forearm / blood supply*
  • Humans
  • Male
  • Middle Aged
  • Models, Cardiovascular
  • Predictive Value of Tests
  • Radial Artery / diagnostic imaging*
  • Radial Artery / physiopathology
  • Radial Artery / surgery*
  • Regional Blood Flow
  • Reproducibility of Results
  • Time Factors
  • Treatment Outcome