Determination of 90Sr-90Y activity in urine samples by using Cherenkov counting

Appl Radiat Isot. 2013 Mar:73:12-6. doi: 10.1016/j.apradiso.2012.11.011. Epub 2012 Nov 22.

Abstract

Cherenkov counting of the (90)Sr-(90)Y pure beta emitters in aqueous samples is an attractive method; but color quenching correction is needed, this being especially significant for urine which is characterized by a strong coloration. A quench correction method based on the external source of some liquid scintillation systems (named ESAR-External Source Area Ratio) was proposed for aqueous solutions. In the present work, the application of the ESAR method for determination of (90)Sr-(90)Y in human urine samples is described.

MeSH terms

  • Humans
  • Radiation Monitoring / methods*
  • Scintillation Counting / methods
  • Strontium Radioisotopes / urine*
  • Yttrium / urine*

Substances

  • Strontium Radioisotopes
  • Yttrium