Complete atrioventricular block during cardiac catheterization: two cases reports in patients without pre-existing conduction abnormalities

Cathet Cardiovasc Diagn. 1990 Jun;20(2):126-30. doi: 10.1002/ccd.1810200213.

Abstract

Third-degree atrioventricular block has been well documented during ventricular catheterization of patients with underlying conduction abnormalities. Two cases reported here describe patients with normal conduction at baseline who sustained complete heart block during ventricular catheterization. Catheterizing physicians should be aware of this risk, which has not been previously reported.

Publication types

  • Case Reports

MeSH terms

  • Cardiac Catheterization / adverse effects*
  • Electrocardiography
  • Female
  • Heart Block / etiology*
  • Heart Conduction System / injuries*
  • Humans
  • Male
  • Middle Aged