Effect of bivalirudin on aortic valve intervention outcomes study: a two-centre registry study comparing bivalirudin and unfractionated heparin in balloon aortic valvuloplasty

EuroIntervention. 2014 Jul;10(3):312-9. doi: 10.4244/EIJV10I3A54.

Abstract

Aims: We sought to assess if bivalirudin use during balloon aortic valvuloplasty (BAV) would affect clinical outcomes compared with heparin.

Methods and results: We compared the outcomes of consecutive patients who underwent elective or urgent BAV with intraprocedural use of bivalirudin or heparin at two high-volume centres. All in-hospital events post BAV were adjudicated by an independent, blinded clinical events committee. Of 427 patients, 223 patients (52.2%) received bivalirudin and 204 (47.8%) received heparin. Compared with patients who received heparin, patients who received bivalirudin had significantly less major bleeding (4.9% vs. 13.2%, p=0.003). Net adverse clinical events (NACE, major bleeding or major adverse cardiovascular events [MACE]) were also reduced (11.2% vs. 20.1%, p=0.01). There was no significant difference in the rates of MACE (mortality, myocardial infarction or stroke, 6.7% vs. 11.3%, p=0.1), or vascular complications (major, 2.7% vs. 2.0%; minor, 4.5% vs. 4.9%; p=0.83). After multivariate analysis controlling for vascular preclosure, the use of bivalirudin remained independently associated with reduced major bleeding (OR 0.37; 95% CI: 0.16 to 0.84; p=0.02) while the association was attenuated in propensity-adjusted analysis (OR 0.44, 95% CI: 0.18 to 1.07, p=0.08).

Conclusions: In this registry of patients with severe aortic stenosis, bivalirudin as compared to heparin resulted in improved in-hospital outcomes post BAV in terms of reduced major bleeding, similar MACE and reduced NACE. If verified in a randomised study and extended to the transcatheter aortic valve implantation (TAVI) population, these results might indicate a potential benefit for patients undergoing such procedures.

Publication types

  • Comparative Study
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Anticoagulants / adverse effects
  • Anticoagulants / therapeutic use*
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Balloon Valvuloplasty* / adverse effects
  • Balloon Valvuloplasty* / mortality
  • Female
  • Florida
  • Hemorrhage / chemically induced
  • Hemorrhage / prevention & control
  • Heparin / adverse effects
  • Heparin / therapeutic use*
  • Hirudins / adverse effects
  • Hospitals, High-Volume
  • Humans
  • Logistic Models
  • Male
  • Multivariate Analysis
  • Myocardial Infarction / etiology
  • Myocardial Infarction / mortality
  • New York City
  • Odds Ratio
  • Peptide Fragments / adverse effects
  • Peptide Fragments / therapeutic use*
  • Propensity Score
  • Recombinant Proteins / adverse effects
  • Recombinant Proteins / therapeutic use
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Severity of Illness Index
  • Stroke / etiology
  • Stroke / mortality
  • Time Factors
  • Treatment Outcome

Substances

  • Anticoagulants
  • Hirudins
  • Peptide Fragments
  • Recombinant Proteins
  • Heparin
  • bivalirudin