Safety of ultrasound-guided fine-needle aspiration of the feline pancreas: a case-control study

J Feline Med Surg. 2015 Oct;17(10):858-63. doi: 10.1177/1098612X14557910. Epub 2014 Nov 4.

Abstract

The safety of fine-needle aspiration (FNA) of the feline pancreas has not been reported. The incidence of complications following ultrasound-guided pancreatic FNA in 73 cats (pancreatic aspirate [PA] cats) with clinical and ultrasonographic evidence of pancreatic disease was compared with complications in two groups of matched control cats also diagnosed with pancreatic disease that either had abdominal organs other than the pancreas aspirated (control FNA, n = 63) or no aspirates performed (control no FNA, n = 61). The complication rate within 48 h of the ultrasound and/or aspirate procedure did not differ among the PA cats (11%), control FNA (14%) or control no FNA (8%) cats. There was no difference in rate of survival to discharge (82%, 84% and 83%, respectively) or length of hospital stay among groups. The cytologic recovery rate for the pancreatic samples was 67%. Correlation with histopathology, available in seven cases, was 86%. Pancreatic FNA in cats is a safe procedure requiring further investigation to establish diagnostic value.

MeSH terms

  • Animals
  • Biopsy, Fine-Needle / methods
  • Biopsy, Fine-Needle / veterinary*
  • Case-Control Studies
  • Cat Diseases / pathology*
  • Cats
  • Pancreas / pathology
  • Pancreatic Diseases
  • Pancreatic Neoplasms / pathology
  • Pancreatic Neoplasms / veterinary*
  • Safety*