Prospectively ECG-triggered high-pitch 80 kVp coronary computed tomography angiography with 30 mL of 270 mg I/mL contrast material and iterative reconstruction

Acta Radiol. 2016 Mar;57(3):287-94. doi: 10.1177/0284185115590433. Epub 2015 Jun 19.

Abstract

Background: The smallest diagnostically appropriate amount of contrast medium should be used in coronary computed tomography angiography (CCTA).

Purpose: To investigate the feasibility of prospectively ECG-triggered high-pitch CCTA using 30 mL of 270 mg I/mL contrast material, 80 kVp, and iterative reconstruction (IR).

Material and methods: Eighty-two consecutive patients underwent CCTA with a prospectively ECG-triggered high-pitch protocol. Forty-three patients were examined at 100 kVp with filtered back projection after 60 mL of 370 mg I/mL contrast material was administered. Another 39 patients were examined at 80 kVp with IR after 30 mL of 270 mg I/mL contrast material was administered. Subjective and objective image quality was evaluated for each patient. Radiation doses were estimated and compared.

Results: Mean attenuation, noise and signal-to-noise ratio in 80 kVp group were significantly lower than in 100 kVp group (all P < 0.05), while there was no significant difference in contrast-to-noise ratio (CNR), although a trend towards a lower CNR in 80 kVp group was observed (P = 0.099). The subjective image quality between the two groups was not significantly different (P = 0.905). The effective dose and iodine load in 80 kVp group were reduced by 54% and 64%, respectively, when compared with 100 kVp group.

Conclusion: Prospectively ECG-triggered high-pitch CCTA at 80 kVp with 30 mL of 270 mg I/mL contrast material and IR is feasible for patients with BMI less than 25 kg/m(2) and reduces radiation dose and iodine load when compared with the standard CCTA protocol.

Keywords: Computed tomography (CT); angiography; contrast material; coronary artery disease; radiation dose.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media*
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging*
  • Electrocardiography*
  • Feasibility Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Radiation Dosage
  • Radiographic Image Enhancement*
  • Radiographic Image Interpretation, Computer-Assisted*
  • Reproducibility of Results
  • Signal-To-Noise Ratio
  • Tomography, X-Ray Computed*

Substances

  • Contrast Media