Low-volume contrast medium protocol for comprehensive cardiac and aortoiliac CT assessment in the context of transcatheter aortic valve replacement

Acad Radiol. 2015 Sep;22(9):1138-46. doi: 10.1016/j.acra.2015.03.018. Epub 2015 Jun 18.

Abstract

Rationale and objectives: To investigate the diagnostic performance of a comprehensive computed tomography (CT) protocol for both cardiac and aortoiliac evaluation of patients considered for transcatheter aortic valve replacement (TAVR) using a single, low-volume contrast medium (CM) injection.

Materials and methods: Forty-four TAVR candidates were retrospectively analyzed. All underwent retrospectively electrocardiogram-gated cardiac CT followed by high-pitch CT angiography of the aortoiliac vasculature using one of two single injection protocols of 320 mgI/mL iodine CM: group A (n = 22), iodine delivery rate-based (1.28 gI/s), 60-mL CM volume, 4.0 mL/s flow rate; group B (n = 22), clinical routine protocol, 100-mL CM volume, 4.0 mL/s flow rate. Mean arterial attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed.

Results: Aortic root and iliofemoral dimensions could be analyzed in all cases. Patient characteristics showed no significant differences. Mean attenuation at the levels of the aortic root (285.8 ± 83.0 HU vs 327.5 ± 70.8 HU, P = .080) and the iliofemoral access route (256.8 ± 88.5 HU vs 307.5 ± 93.2 HU, P = .071), as well as SNR and CNR were nonsignificantly lower in group A compared to group B. Subjective image quality was equivalent.

Conclusions: In multimorbid TAVR patients, the performance of a combined CT protocol using a single low-volume CM bolus is feasible with maintained image quality compared to a standard protocol.

Keywords: Aortic stenosis; aortoiliac CT angiography; contrast medium; dual-source CT; transcatheter aortic valve replacement.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / surgery
  • Aortography / methods*
  • Cardiac-Gated Imaging Techniques / methods
  • Computed Tomography Angiography / methods*
  • Contrast Media / administration & dosage*
  • Feasibility Studies
  • Female
  • Heart / diagnostic imaging*
  • Humans
  • Iliac Artery / diagnostic imaging*
  • Image Processing, Computer-Assisted / methods
  • Male
  • Patient Care Planning
  • Radiation Dosage
  • Retrospective Studies
  • Signal-To-Noise Ratio
  • Tomography, X-Ray Computed / methods*
  • Transcatheter Aortic Valve Replacement / methods*
  • Triiodobenzoic Acids / administration & dosage

Substances

  • Contrast Media
  • Triiodobenzoic Acids
  • iodixanol