Safety and effectiveness evaluation of a domestic peritoneal dialysis fluid packed in non-PVC bags: study protocol for a randomized controlled trial

Trials. 2015 Dec 29:16:592. doi: 10.1186/s13063-015-1131-1.

Abstract

Background: Peritoneal dialysis is an important type of renal replacement therapy for uremic patients. In peritoneal dialysis, fluids fill in and flow out of the abdominal cavity three to five times per day. Usually, the fluid is packed in a polyvinyl chloride (PVC) bag. Safety concerns have arisen over di-(2-ethylhexyl) phthalate, which is essential in the formation of PVC materials. In 2011, the National Development and Reform Commission of China released a catalog of industrial structural adjustments, mandating the elimination of PVC bags for intravenous infusion and food containers. Although bags for peritoneal dialysis fluid were not included in the elimination list, several manufacturers began to develop new materials for fluid bags. HUAREN peritoneal dialysis fluid consists of the same electrolytes and buffer agent as in Baxter fluid, but is packed in bags that do not contain PVC. This multicenter randomized controlled trial was designed to compare peritoneal dialysis fluid packed in non-PVC-containing and PVC-containing bags. Further, the study sought to determine the proper dose of peritoneal dialysis fluid and the actual survival rates of Chinese patients undergoing peritoneal dialysis.

Methods/design: The study participants are adults undergoing continuous ambulatory peritoneal dialysis for 30 days to 6 months. All eligible patients are randomized (1:1) to peritoneal dialysis with Baxter and HUAREN dialysis fluids (initial dose, 6 l/day), with dosages adjusted according to a unified protocol. The primary outcomes are the 1-, 2-, 3-, 4-, and 5-year overall survival rates. Secondary outcome measures include technique survival rates, reductions in estimated glomerular filtration rate, nutritional status, quality of life, cardiovascular events, medical costs and drop-out rates. Safety outcome measures include adverse events, changes in vital signs and laboratory parameters, peritonitis, allergies, and quality of products.

Discussion: This study is the first to evaluate the long-term safety and effectiveness of a non-PVC packed peritoneal dialysis fluid. The effects of plasticizer on patient long-term survival will be determined. The characteristics of Chinese patients undergoing peritoneal dialysis will be determined, including proper dose, technique survival rates, patient survival rates, and medical costs.

Trial registration: Clinicaltrials.gov NCT01779557 .

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • China
  • Clinical Protocols
  • Comparative Effectiveness Research
  • Dialysis Solutions / adverse effects
  • Dialysis Solutions / chemistry
  • Dialysis Solutions / therapeutic use*
  • Drug Contamination / prevention & control*
  • Drug Packaging*
  • Female
  • Health Status
  • Home Care Services*
  • Humans
  • Kidney Failure, Chronic / diagnosis
  • Kidney Failure, Chronic / mortality
  • Kidney Failure, Chronic / therapy*
  • Male
  • Peritoneal Dialysis, Continuous Ambulatory / adverse effects
  • Peritoneal Dialysis, Continuous Ambulatory / methods*
  • Peritoneal Dialysis, Continuous Ambulatory / mortality
  • Plasticizers / chemistry*
  • Polyvinyl Chloride / chemistry*
  • Prospective Studies
  • Research Design
  • Risk Factors
  • Survival Analysis
  • Time Factors
  • Treatment Outcome

Substances

  • Dialysis Solutions
  • Plasticizers
  • Polyvinyl Chloride

Associated data

  • ClinicalTrials.gov/NCT01779557