Systematic evaluation of data-independent acquisition for sensitive and reproducible proteomics-a prototype design for a single injection assay

J Mass Spectrom. 2016 Jan;51(1):1-11. doi: 10.1002/jms.3716.

Abstract

Data-independent acquisition (DIA)-based proteomics has become increasingly complicated in recent years because of the vast number of workflows described, coupled with a lack of studies indicating a rational framework for selecting effective settings to use. To address this issue and provide a resource for the proteomics community, we compared 12 DIA methods that assay tryptic peptides using various mass-isolation windows. Our findings indicate that the most sensitive single injection LC-DIA method uses 6 m/z isolation windows to analyze the densely populated tryptic peptide range from 450 to 730 m/z, which allowed quantification of 4465 Escherichia coli peptides. In contrast, using the sequential windowed acquisition of all theoretical fragment-ions (SWATH) approach with 26 m/z isolation windows across the entire 400-1200 m/z range, allowed quantification of only 3309 peptides. This reduced sensitivity with 26 m/z windows is caused by an increase in co-eluting compounds with similar precursor values detected in the same tandem MS spectra, which lowers the signal-to-noise of peptide fragment-ion chromatograms and reduces the amount of low abundance peptides that can be quantified from 410 to 920 m/z. Above 920 m/z, more peptides were quantified with 26 m/z windows because of substantial peptide (13) C isotope distributions that parse peptide ions into separate isolation windows. Because reproducible quantification has been a long-standing aim of quantitative proteomics, and is a so-called trait of DIA, we sought to determine whether precursor-level chromatograms used in some methods rather than their fragment-level counterparts have similar precision. Our data show that extracted fragment-ion chromatograms are the reason DIA provides superior reproducibility. Copyright © 2015 John Wiley & Sons, Ltd.

Keywords: DIA; PAcIFIC; Protalizer; SWATH; label-free quantification.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, Liquid / methods
  • Escherichia coli / chemistry*
  • Escherichia coli Proteins / chemistry*
  • Flow Injection Analysis / methods
  • Peptides / analysis*
  • Proteome / chemistry*
  • Proteomics / methods*
  • Reproducibility of Results
  • Software
  • Tandem Mass Spectrometry / methods*

Substances

  • Escherichia coli Proteins
  • Peptides
  • Proteome