Patency rates of dysfunctional central hemodialysis venous catheter: Comparison between catheter exchange alone and catheter exchange with fibrin sheath angioplasty

Diagn Interv Imaging. 2019 Mar;100(3):157-162. doi: 10.1016/j.diii.2018.08.013. Epub 2018 Sep 24.

Abstract

Purpose: The purpose of this study was to compare patency rates and risk of obstruction of catheter exchange (CE) with that of CE with fibrin sheath angioplasty (CE+FSA) in dysfunctional tunneled central hemodialysis venous catheter (CHVC).

Materials and methods: A total of 107 consecutive patients with dysfunctional CHVC were retrospectively included. There were 66 men and 41 women with a mean age of 67.8±12.5 (SD) years (range: 23.0-86.0 years). Seventy-three of 107 patients (68.2%) underwent CE procedure and 34 of 107 (31.8%) underwent CE+FSA. Kaplan-Meier log-rank test and multivariate Cox regression analyses were performed to determine patency rates and risk of obstruction according to type of endovascular procedure.

Results: Patency rates after endovascular procedures at 3, 6, 12, 24 and 36 months follow up were 75%, 75%, 65%, 65% and 65% in CE+FSA group and 70%, 65%, 62%, 30% and 0% in CE group. Mean time until obstruction of CHVC was 778.4 days after CE+FSA and 497 days after CE (P=0.211). Endovascular procedure was unrelated to risk of obstruction in adjusted model (HR=1.34; P=0.515).

Conclusions: Our findings suggest that both techniques are equivalent in terms of patency and safety results, so other aspects as cost assessment should be considered when choosing between both techniques.

Keywords: Catheter exchange; Central venous catheter; Fibrin sheath angioplasty; Hemodialysis; Patency rate.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Angioplasty*
  • Central Venous Catheters*
  • Combined Modality Therapy
  • Equipment Failure*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Renal Dialysis*
  • Retrospective Studies
  • Risk Factors
  • Vascular Patency*
  • Young Adult