One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in patients presenting with acute myocardial infarction: Insight from the ULISSE registry

Catheter Cardiovasc Interv. 2019 Dec 1;94(7):972-979. doi: 10.1002/ccd.28305. Epub 2019 Apr 29.

Abstract

Background: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI).

Methods: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR).

Results: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF.

Conclusions: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.

Keywords: acute myocardial infarction; biodegradable-polymer sirolimus-eluting coronary stent; percutaneous coronary interventions; stent thrombosis.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Coronary Thrombosis / etiology
  • Drug-Eluting Stents*
  • Female
  • Humans
  • Italy
  • Male
  • Middle Aged
  • Myocardial Infarction / diagnostic imaging
  • Myocardial Infarction / mortality
  • Myocardial Infarction / therapy*
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Polymers / chemistry*
  • Progression-Free Survival
  • Prosthesis Design
  • Recurrence
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Sirolimus / administration & dosage*
  • Sirolimus / adverse effects
  • Time Factors

Substances

  • Cardiovascular Agents
  • Polymers
  • Sirolimus