Is high-sensitivity troponin, alone or in combination with copeptin, sensitive enough for ruling out NSTEMI in very early presenters at admission? A post hoc analysis performed in emergency departments

BMJ Open. 2019 Jun 16;9(6):e023994. doi: 10.1136/bmjopen-2018-023994.

Abstract

Objectives: Copeptin and high-sensitivity cardiac troponin (HS-cTn) assays improve the early detection of non-ST-segment elevation myocardial infarction (NSTEMI). Their sensitivities may, however, be reduced in very early presenters.

Setting: We performed a post hoc analysis of three prospective studies that included patients who presented to the emergency department for chest pain onset (CPO) of less than 6 hours.

Participants: 449 patients were included, in whom 12% had NSTEMI. CPO occurred <2 hours from ED presentation in 160, between 2 and 4 hours in 143 and >4 hours in 146 patients. The prevalence of NSTEMI was similar in all groups (9%, 13% and 12%, respectively, p=0.281).

Measures: Diagnostic performances of HS-cTn and copeptin at presentation were examined according to CPO. The discharge diagnosis was adjudicated by two experts, including cardiac troponin I (cTnI). HS-cTn and copeptin were blindly measured.

Results: Diagnostic accuracies of cTnI, cTnI +copeptin and HS-cardiac troponin T (HS-cTnT) (but not HS-cTnT +copeptin) lower through CPO categories. For patients with CPO <2 hours, the choice of a threshold value of 14 ng/L for HS-cTnT resulted in three false negative (Sensitivity 80%(95% CI 51% to 95%); specificity 85% (95% CI 78% to 90%); 79% of correctly ruled out patients) and that of 5 ng/L in two false negative (sensitivity 87% (95% CI 59% to 98%); specificity 58% (95% CI 50% to 66%); 52% of correctly ruled out patients). The addition of copeptin to HS-cTnT induced a decrease of misclassified patients to 1 in patients with CPO <2 hours (sensitivity 93% (95% CI 66% to 100%); specificity 41% (95% CI 33% to 50%)).

Conclusion: A single measurement of HS-cTn, alone or in combination with copeptin at admission, seems not safe enough for ruling out NSTEMI in very early presenters (with CPO <2 hours).

Trial registration number: DC-2009-1052.

Keywords: chest pain; chest pain onset; copeptin; high sensitive cardiac troponin; non st-elevation acute myocardial infarction; very early presenters.

MeSH terms

  • Adult
  • Aged
  • Biomarkers / blood
  • Chest Pain / etiology
  • Emergency Service, Hospital / statistics & numerical data
  • Female
  • Glycopeptides / blood*
  • Humans
  • Male
  • Middle Aged
  • Non-ST Elevated Myocardial Infarction / blood
  • Non-ST Elevated Myocardial Infarction / diagnosis*
  • Non-ST Elevated Myocardial Infarction / epidemiology
  • Predictive Value of Tests
  • Prospective Studies
  • Time Factors
  • Troponin I / blood*

Substances

  • Biomarkers
  • Glycopeptides
  • Troponin I
  • copeptins