One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in diabetic patients: Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry)

Catheter Cardiovasc Interv. 2020 Aug;96(2):255-265. doi: 10.1002/ccd.28694. Epub 2020 Jan 6.

Abstract

Background: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients.

Methods: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year.

Results: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation.

Conclusions: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.

Keywords: biodegradable polymer sirolimus-eluting stent; diabetes mellitus; percutaneous coronary intervention.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Diabetes Mellitus* / diagnosis
  • Diabetes Mellitus* / mortality
  • Drug-Eluting Stents*
  • Female
  • Humans
  • Italy
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Prospective Studies
  • Prosthesis Design
  • Registries
  • Risk Assessment
  • Risk Factors
  • Sirolimus / administration & dosage*
  • Sirolimus / adverse effects
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Sirolimus