Abstract

Background: The role of computed tomography (CT) for diagnosis and surgical planning for craniosynostosis (CS) is well-established. The aim of this study was to quantify the cumulative medical radiation exposure from CT in patients with CS at a tertiary care children's hospital.

Methods: Medical records of patients who presented at < 2 years of age and underwent surgical intervention for CS were examined for demographic information. Effective radiation dose (ERD) in mSv was calculated for each head CT. Descriptive statistics and ANOVA were performed. Mean ± SD is reported; p < 0.05 was considered significant.

Results: Two hundred seventy-two patients met inclusion criteria: 241 nonsyndromic and 31 with syndromic diagnoses. For nonsyndromic patients, mean age at first head CT was 6.0 ± 4.9 months, mean number of CT scans obtained was 2.1 ± 1.1, and the mean total combined ERD was 9.1 ± 4.8 mSv. CT scans obtained at < 6 months of age had a significantly greater ERD than those obtained at > 6 months, 5.3 ± 1.9 versus 4.3 ± 1.4 mSv, respectively (p = 0.001).

Conclusions: Patients with nonsyndromic CS undergo 2 CT scans on average related to their diagnosis, with a mean total ERD of 9.1 mSv; this is equivalent to 1.5 years of the average annual background radiation dose a person living in the USA will encounter from environmental radiation, medical exposures, and consumer products. A CT obtained at < 6 months is associated with a higher ERD; thus, we recommend delaying imaging from the initial presentation to the time of pre-operative planning when possible.

Keywords: Computed tomography; Craniosynostosis; Radiation exposure.