High sensitivity troponin - Six hours is the magic number

Am J Emerg Med. 2022 Nov:61:52-55. doi: 10.1016/j.ajem.2022.08.037. Epub 2022 Aug 19.

Abstract

Background: High sensitivity troponin assays have become widespread for emergency department evaluation of acute chest pain. We assessed if a high sensitivity troponin under the 99th percentile upper reference limit drawn at 6 h or greater from symptom onset could safely rule out acute coronary syndrome in patients who did not meet the rapid rule-out strategy.

Methods: We conducted a multicenter retrospective study examining emergency department patients with chest pain who did not meet rapid-rule out criteria and were admitted for further evaluation. Among these admitted patients, we assessed the rate of clinically relevant adverse cardiac events (death, cardiac or respiratory arrest, STEMI, or life-threatening arrhythmia) and NSTEMI in patients with high sensitivity troponin less than the 99th percentile value obtained after at least 6 h of chest pain.

Results: Out of 1187 patients admitted, we found 30 clinically relevant adverse cardiac events, all of which occurred in patients admitted for another compelling reason or ischemic ECG. 36 patients had an NSTEMI, of which 33 were identified with high sensitivity troponin greater than 99th percentile upper reference limit within 6 h of chest pain onset. This left 0 clinically relevant adverse cardiac events and 3 NSTEMI among the 429 patients with high sensitivity troponin less than the 99th percentile at 6 h and nonischemic ECG and no other compelling reason for admission.

Conclusion: This study assessed patients with chest pain with high sensitivity troponin values between 3 ng/L and the 99th percentile upper reference limit after 6 h of chest pain and found that they have a low rate of clinically relevant adverse cardiac events and NSTEMI.

Keywords: Acute coronary syndrome; Cardiology; NSTEMI; Troponin.

Publication types

  • Multicenter Study

MeSH terms

  • Biomarkers
  • Chest Pain / diagnosis
  • Chest Pain / etiology
  • Humans
  • Myocardial Infarction* / diagnosis
  • Non-ST Elevated Myocardial Infarction*
  • Retrospective Studies
  • Sensitivity and Specificity
  • Troponin I
  • Troponin T

Substances

  • Troponin I
  • Biomarkers
  • Troponin T