Hardware Impingement Is Associated With Shorter Screw Length in Patients Treated With In Situ Screw Fixation for Slipped Capital Femoral Epiphysis: An In Vivo Arthroscopic Evaluation

Arthrosc Sports Med Rehabil. 2022 Aug 1;4(5):e1623-e1628. doi: 10.1016/j.asmr.2022.06.005. eCollection 2022 Oct.

Abstract

Purpose: To determine the incidence of screw impingement on dynamic exam during hip arthroscopy in patients undergoing treatment for femoroacetabular impingement after previous slipped capital femoral epiphysis fixation and to evaluate screw characteristics with hardware impingement.

Methods: A retrospective review from 2008 to 2020 was performed of slipped capital femoral epiphysis (SCFE) patients that underwent arthroscopy for symptoms of hip impingement. Patients underwent a dynamic exam under direct arthroscopic visualization to assess for sources of impingement, including bony anatomy and fixation hardware. Slip angle was calculated on lateral radiographs prior to arthroscopy, and screw length was noted in the initial operative reports at treatment of SCFE and reported in millimeters. Normality of data was assessed using Shapiro-Wilk tests, with statistical analysis performed using independent sample t-tests, Mann-Whitney U-nonparametric tests, and multivariable logistic regression. An alpha level of <0.05 was used to indicate statistical significance.

Results: Thirty-nine hips were included, with 13 (33.3%) having screw impingement on dynamic exam. Slip angle was found to be increased in the screw impingement group (42.4° vs 35.5°; P = .11). Screw length was noted to be significantly shorter in the screw impingement group (53.1 vs 61.6 mm; P = .021). The presence of screw impingement was found to be associated with shorter screw length (β = -0.172, R 2 = 0.329; P = .036).

Conclusions: Shorter screws (55 mm or less) are at greater risk of causing hardware hip impingement after in situ SCFE fixation. When considering hip arthroscopy for the treatment of femoroacetabular impingement in patients with a previous SCFE, hardware impingement and subsequent hardware removal should be considered in hips with shorter screws and in hips that show objective hardware impingement on dynamic exam.

Level of evidence: Level IV, therapeutic case series.