Umbilical cord serum insulin-like growth factor-1 levels of infants of diabetic mothers are correlated with diastolic dysfunction detected by tissue Doppler echocardiography

Eur J Pediatr. 2023 Mar;182(3):1281-1288. doi: 10.1007/s00431-022-04792-2. Epub 2023 Jan 12.

Abstract

Tissue Doppler echocardiography (TDI) is a convenient method to detect cardiac dysfunction in the infants of diabetic mothers (IDMs). Umbilical cord serum insulin-like growth factor-1 (IGF-1) is known to be higher in IDMs. We aimed to determine whether there is a relation between diastolic functions examined by TDI and cord serum IGF-1 levels of IDMs. Cord serum IGF-1 levels of 32 IDMs and 22 healthy infants were measured. The cardiac functions of the infants were evaluated by M-Mode and TDI. For statistical analysis, Mann-Whitney U and Spearman correlation tests were used for continuous variables, and the chi-square test was used for categorical variables. The cord serum IGF-1 levels of the IDMs were higher (p = 0.000). The left ventricle (LV) e', LVa', LV e'/a', and LV Tei index, indicating left ventricular diastolic dysfunction in IDMs, were detected (LV e' p = 0.016; LV a' p = 0.003; LV e'/ a' p = 0.000; LV Tei index p = 0.023). IDMs' cord serum IGF-1 levels were found weakly correlated with the interventricular septum (IVS) and left ventricle posterior wall (LVPW) thicknesses in M-Mode and LV e' and LV e'/a' in TDI (IVS r = 0.357, p = 0.008; LVPW r = 0.289, p = 0.034; LV e' r = 0.297, p = 0.029; LV e'/ a' r = 0.031, p = 0.014).

Conclusion: To our knowledge, this is the first study to examine the relationship between cord serum IGF-1 levels and diastolic functions of IDMs assessed by TDI. A weak correlation was found between IGF-1 levels and IVS and LVPW thicknesses in M-Mode and LV e' and LV e'/a' parameters in TDI, revealing diastolic dysfunction in IDMs.

What is known: • The umbilical cord blood serum IGF-1 level of IDMs is higher than in infants of healthy mothers. • Diastolic dysfunction is a well-studied and frequently observed consequence in IDMs.

What is new: • This is the first study to examine the relationship between cord serum IGF-1 levels and diastolic functions of IDMs assessed by TDI. • A weak correlation was detected between the median cord serum IGF-1 level of IDMs and the median values of IVS, LVPW, LV e', LV a', LV e'/a' ratio.

Keywords: Doppler echocardiography; Gestational diabetes; Infant; Insulin-like growth factor I; Tissue Doppler echocardiography.

Publication types

  • Review

MeSH terms

  • Diabetes Mellitus*
  • Diastole
  • Echocardiography, Doppler
  • Female
  • Humans
  • Infant
  • Insulin-Like Growth Factor I
  • Mothers
  • Ventricular Dysfunction, Left* / diagnostic imaging
  • Ventricular Dysfunction, Left* / etiology

Substances

  • Insulin-Like Growth Factor I