Rupture of the Flexor Pollicis Longus Tendon Involved between the Radial Shaft and the Volar Locking Plate

J Wrist Surg. 2023 Apr 5;12(6):540-542. doi: 10.1055/s-0043-1761424. eCollection 2023 Dec.

Abstract

We report the case of a 61-year-old woman with right-sided flexor pollicis longus (FPL) tendon ruptured a month after volar locking plate fixation. Five months after the initial operation, hardware removal and reconstruction of the FPL tendon with the ipsilateral palmaris longus were performed. The proximal stump of the ruptured FPL tendon was found in the space between the distal radius and plate.

Keywords: FPL tendon; distal radius; fracture; volar locking plate.