Photon counting fibre optic distributed temperature sensing with a CMOS SPAD array

Opt Express. 2024 Feb 12;32(4):6481-6493. doi: 10.1364/OE.506964.

Abstract

Time-resolved fibre optic Raman distributed temperature sensing (DTS) measurements experience long measurement times due to a weak backscattered Raman signal inside optical fibres or limited detector count rates. Here, improvements to previous work based on individual detectors are demonstrated using a 512 pixel complementary-metal-oxide semiconductor (CMOS) single-photon avalanche diode (SPAD) line sensor array with integrated (on-chip) timing electronics. Multiplexed single photon counting increases count rate and decreases measurement time for practical applications. This allows temperature to be measured every 0.5 m with 0.7 °C accuracy and a 10 s measurement time using a 13.0 m optical fibre, performance over longer distance is also investigated.