Frequency of Locator Legacy Insert Changes With Implant Overdentures in a UK Population

Int J Prosthodont. 2024 Mar 11;0(0):1-12. doi: 10.11607/ijp.8778. Online ahead of print.

Abstract

Purpose: To determine the frequency of insert changes for combined maxillary and mandibular implant overdentures (IOD) using the Locator Legacy system. A secondary objective was to assess the survival of dental implants with IODs.

Materials and methods: This retrospective audit reviewed clinical records with up to 12 years follow up from 785 patients who received IODs using the Locator system at a dental hospital. From these, 151 had a combined maxillary opposed by a mandibular IOD and from this, 37 had data retrieved using a minimum data set. The frequency of insert change was recorded and descriptive analysis was provided by means and standard deviations for continuous variables. Frequencies of categorical values were reported as percentages.

Results: 222 implants were placed on 21 men, 16 women with a mean age 67.5 years (SD 8.8). All patients were reviewed at least once. Maxillary and mandibular IODs experienced 1.9 (SD 2.0) and 1.2 (SD 1.2) mean insert changes per patient, respectively. The mean time (SD) between initial and first insert change for maxillary and mandibular IODs was 3.4 months (SD 3.2) and 6.4 months (SD 7.2) and between the first and second insert change was 9.9 months (SD 9.0) and 10.0 months (SD 8.3), respectively. Implant failure was 21.6% and 2.7% in the maxilla and mandible respectively.

Conclusions: Clinicians should anticipate the first insert change around 3 months for maxillary IOD and 6 months for mandibular IOD. Subsequently, the second insert change to be around 10 months for both maxillary and mandibular IODs.