[Comparative study of minimally invasive titanium elastic nail and steel plate on the treatment of fracture of tibiofibular fracture in adults]

Zhongguo Gu Shang. 2024 Apr 25;37(4):352-7. doi: 10.12200/j.issn.1003-0034.20230167.
[Article in Chinese]

Abstract

Objective: To compare the clinical outcomes of using elastic intramedullary nail and plate to fix fibular fracture.

Methods: The 60 patients with tibiofibular fractures admitted from January 2015 to December 2022 were divided into two groups:intramedullary nail group and plate group, 30 cases each, intramedullary nail group was treated with elastic intramedullary nail fixation group, plate group was treated with steel plate and screw fixation group. Intramedullary nail group, there were 18 males and 12 females, aged from 22 to 75 years old with an average of (39.4±9.8) years old, including 24 cases of traffic accidents injury, 6 cases of falling injury, 23 cases of closed fractures, 7 cases of open fractures. Steel plate group, there were 15 males and 15 females, aged from 24 to 78 years old with an average of (38.6±10.2) years old. The 22 cases were injured by traffic accident, 8 cases were injured by falling. The 24 cases were closed fractures and 6 cases were open fractures. The operation time, intraoperative bleeding, American Orthopedic Foot and Ankle Society (AOFAS) ankle and hind foot scores, clinical healing time of fibula and the incidence of wound complications were compared between the two groups.

Results: The patients in both groups were followed up for 6 to 21 months, with an average of (14.0±2.8) months. Compared with plate group, intramedullary nail group had shorter operative time, less bleeding, shorter clinical healing time of fibula, and lower infection rate of incision, and the difference was statistically significant (P<0.05). There were 2 cases of delayed healing in intramedullary nail group, 1 case of nonunion in plate group, and 2 cases of delayed healing in plate group, and there was no statistically significant difference between the two groups (P>0.05). In the last follow-up, according to the AOFAS scoring standard, the ankle function in intramedullary nail group was excellent in 17 cases, good in 12 cases, fair in 1 case, with an average of (88.33±4.57) points, while in plate group, excellent in 16 cases, good in 10 cases, fair in 4 cases, with an average of (87.00±4.14) points;There was no statistical difference between the two groups (P>0.05).

Conclusion: Elastic intramedullary nail has the advantages of short operation time, less intraoperative bleeding, short fracture healing time and less incision complications in the treatment of fibular fracture, which is worthy of clinical application.

Keywords: Adults; Elastic intramedullary nail; Internal fixation; Tibial and fibular fracture.

Publication types

  • Comparative Study
  • English Abstract

MeSH terms

  • Adult
  • Aged
  • Bone Nails*
  • Bone Plates*
  • Female
  • Fibula* / injuries
  • Fibula* / surgery
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods
  • Fracture Fixation, Intramedullary / instrumentation
  • Fracture Fixation, Intramedullary / methods
  • Humans
  • Male
  • Middle Aged
  • Minimally Invasive Surgical Procedures / methods
  • Steel
  • Tibial Fractures* / surgery
  • Titanium
  • Young Adult

Substances

  • Titanium
  • Steel