Mechanism of Silica Nanoparticle-Induced Particulate Fouling in Vacuum Membrane Distillation

Membranes (Basel). 2024 Mar 27;14(4):76. doi: 10.3390/membranes14040076.

Abstract

Membrane distillation (MD) is a process driven by the vapor pressure difference dependent on temperature variation, utilizing a hydrophobic porous membrane. MD operates at low pressure and temperature, exhibiting resilience to osmotic pressure. However, a challenge arises as the membrane performance diminishes due to temperature polarization (TP) occurring on the membrane surface. The vacuum MD process leverages the application of a vacuum to generate a higher vapor pressure difference, enhancing the flux and mitigating TP issues. Nevertheless, membrane fouling leads to decreased performance, causing membrane wetting and reducing the ion removal efficiency. This study investigates membrane fouling phenomena induced by various silica nanoparticle sizes (400, 900, and 1300 nm). The patterns of membrane fouling, as indicated by the flux reduction, vary depending on the particle size. Distinct MD performances are observed with changes in the feed water temperature and flow rate. When examining the membrane fouling mechanism for particles with a porosity resembling actual particulate materials, a fouling form similar to the solid type is noted. Therefore, this study elucidates the impact of particulate matter on membrane fouling under diverse conditions.

Keywords: membrane distillation; membrane fouling; vacuum membrane distillation.