Planimetry of orifice area in aortic stenosis using multiplane transesophageal echocardiography

J Am Coll Cardiol. 1993 Aug;22(2):529-34. doi: 10.1016/0735-1097(93)90060-e.

Abstract

Objectives: The purpose of this study was to investigate whether the orifice area in aortic stenosis can be determined accurately and reliably by multiplane transesophageal echocardiography.

Background: Monoplane transesophageal echocardiography has been used for planimetry of aortic valve orifice areas; however, obtaining a precise short-axis view is sometimes impossible.

Methods: In 41 consecutive patients with known valvular calcific aortic stenosis (20 men, mean age 64 +/- 9 years), aortic valve orifice area was measured by planimetry using a multiplane transesophageal echocardiographic probe that allows full rotation of the cross-sectional plane. Results were compared with invasive measurements obtained by the Gorlin formula and areas determined noninvasively by transthoracic echocardiography using the continuity equation.

Results: Multiplane transducer technology enabled the rotation of the cross-sectional plane from an exactly aligned long-axis view of the stenosed valve to a precise short-axis view without moving the tip of the echocardiographic probe, thus achieving an orifice cross section at a level predetermined in the long-axis view. Planimetry was feasible in 38 patients (93%). In three patients with pinhole stenosis (area determined by the Gorlin formula < 0.4 cm2), the valve area could not be exactly delineated. Correlation between areas derived by transesophageal echocardiographic planimetry (0.56 +/- 0.31 cm2) and by the Gorlin formula (0.58 +/- 0.31 cm2) was excellent (r = 0.95; standard deviation of regression [SDR] = 0.054; Y = 0.92X + 0.085, where Y = Gorlin area and X = planimetry area). Correlation between Gorlin- and continuity equation-derived areas (0.65 +/- 0.46 cm2) was r = 0.79; for continuity equation- and transesophageal planimetry-derived areas it was r = 0.83. Severe aortic stenosis (valve area < or = 0.75 cm2) was predicted with high sensitivity (96%) and specificity (88%).

Conclusions: Multiplane transesophageal echocardiography is a practical and accurate clinical tool for the assessment of the severity of aortic stenosis.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve Stenosis / diagnostic imaging*
  • Echocardiography / methods*
  • Esophagus
  • Evaluation Studies as Topic
  • Female
  • Humans
  • Male
  • Middle Aged