Abstract

Methods: Thirty-two patients with clinical node-negative breast cancer underwent sentinel node localization study as part of a National Cancer Institute-sponsored multicenter trial. Anatomical and histopathologic characteristics of sentinel lymph node (SLN) and a kinetic analysis of nodal uptake were studied. Patients were injected with 1 mCi/4 ml unfiltered 99mTc-sulfur colloid in four divided doses around the palpable lesion or immediately adjacent to the excision cavity if prior biopsy was performed. SLN biopsy was performed 1.5-6 hr (mean = 3 hr) postinjection. Intraoperative localization was performed using a gamma probe. All patients underwent complete axillary dissection.

Results: SLN was identified in 30 of 32 (94%) patients. There were no false-negative SLN biopsies.

Conclusion: This study supports the clinical validity of SLN biopsy in breast cancer and confirms that, unlike the blue dye technique, the learning curve with unfiltered 99mTc-sulfur colloid and the gamma detection probe is short, and SLN localization is achievable in over 90% of cases by surgeons with modest experience. The use of unfiltered 99mTc-sulfur colloid (larger particle size) with larger injected volume permits effective localization of SLNs.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adult
  • Aged
  • Axilla
  • Biopsy
  • Breast Neoplasms / pathology*
  • Carcinoma, Ductal, Breast / diagnostic imaging*
  • Carcinoma, Ductal, Breast / secondary*
  • Female
  • Humans
  • Lymph Node Excision
  • Lymph Nodes / diagnostic imaging*
  • Lymph Nodes / pathology
  • Lymphatic Metastasis
  • Middle Aged
  • Prospective Studies
  • Radionuclide Imaging
  • Radiopharmaceuticals*
  • Technetium Tc 99m Sulfur Colloid*

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sulfur Colloid