One-stage explant-implant procedure of exposed porous orbital implants

Acta Ophthalmol. 2012 May;90(3):210-4. doi: 10.1111/j.1755-3768.2010.01914.x. Epub 2010 May 26.

Abstract

Purpose: To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant.

Methods: Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3) orbital implant from January 2000 to February 2009 were included. The patient records were reviewed; patients were interviewed by telephone and invited for a clinical examination. Histopathological examination was carried out on the removed implants. Main outcome measures were: presence of exposure of the new implant or not, patient graded satisfaction with the cosmetic result, and presence of poor motility.

Results: None of the new implants became exposed or infected in the follow-up period of 25 [3-94] months (median [range]). The patients scored their satisfaction with the cosmetic result to a median score of 9 (range 5-10). Poor motility was present in six of 17 patients. Micro-organisms were identified in three removed implants and signs of inflammation were present in 20 removed implants.

Conclusions: If a decision of implant removal has been made, it is safe to replace the implant at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Biocompatible Materials
  • Durapatite
  • Eye Enucleation
  • Eye Evisceration
  • Female
  • Humans
  • Male
  • Middle Aged
  • Ophthalmologic Surgical Procedures*
  • Orbit / surgery*
  • Orbital Implants*
  • Patient Satisfaction
  • Polyethylenes
  • Postoperative Complications*
  • Prosthesis Implantation
  • Reoperation
  • Retrospective Studies
  • Risk Factors
  • Surgical Wound Dehiscence / surgery*
  • Young Adult

Substances

  • Biocompatible Materials
  • Medpor
  • Polyethylenes
  • Durapatite