[Evaluating the effectiveness and safety of diode laser trans-scleral thermotherapy of the ciliary body as a treatment for refractory glaucoma]

Vestn Oftalmol. 2014 Sep-Oct;130(5):64-6.
[Article in Russian]

Abstract

Objective: To evaluate the effectiveness and safety of diode laser trans-scleral thermotherapy (TSTT) in cyclodestruction for refractory glaucoma (RG).

Material and methods: The proposed cyclodestructive procedure was performed on 87 patients with severe and terminal RG (stages III and IV) at power levels of 0.4-0.5 W with exposure times of 15-25 seconds.

Results: The incidence of severe inflammatory response was less than that after well-known cyclodestructive procedures. The average reduction of intraocular pressure at the first day after surgery (considering all observations) was 10.45 +/- 7.23 mmHg. In all cases after TSTT of the ciliary body the pain resolved within the first day.

Conclusion: The effectiveness of the new method is comparable to that of other methods of cyclodestruction, however, the proposed TSTT technique is much safer than the conventional trans-scleral cyclophotocoagulation.

Publication types

  • English Abstract

MeSH terms

  • Aged
  • Ciliary Body / surgery
  • Comparative Effectiveness Research
  • Female
  • Glaucoma / physiopathology
  • Glaucoma / surgery*
  • Humans
  • Hyperthermia, Induced* / adverse effects
  • Hyperthermia, Induced* / instrumentation
  • Hyperthermia, Induced* / methods
  • Intraocular Pressure
  • Laser Therapy* / adverse effects
  • Laser Therapy* / instrumentation
  • Laser Therapy* / methods
  • Lasers, Semiconductor* / adverse effects
  • Lasers, Semiconductor* / therapeutic use
  • Male
  • Pain, Postoperative / prevention & control*
  • Postoperative Hemorrhage / etiology
  • Postoperative Hemorrhage / prevention & control*
  • Sclera / surgery
  • Treatment Outcome