Terson's Syndrome: Diagnostic Comparison of Ocular Sonography and CT

J Neuroimaging. 2016 Mar-Apr;26(2):247-52. doi: 10.1111/jon.12285. Epub 2015 Aug 6.

Abstract

Background and purpose: To assess the accuracy of ocular B-mode sonography and of standard head computed tomography (CT) as screening tools for intraocular hemorrhages related to subarachnoid hemorrhage (SAH).

Methods: 46 patients with spontaneous SAH were examined using ocular B-mode sonography and underwent funduscopy as gold standard for detection of ocular hemorrhages (OH). Additionally, all head CT scans done during the hospital stay of the study population were rated by a neuroradiologist for the presence of OH.

Results: Funduscopy revealed vitreous and/or preretinal hemorrhages in ten eyes and retinal hemorrhages in nine eyes. In comparison with funduscopy, ocular sonography showed a sensitivity and specificity for the detection of vitreous and/or preretinal hemorrhages of 100%, while identification of retinal hemorrhages was less reliable with a sensitivity/specificity of 44%/100%. Standard head CT showed a lower sensitivity/specificity of 60%/96% for vitreous and/or preretinal hemorrhages, and 32%/95% for the diagnosis of any ocular bleeding.

Conclusion: Ocular sonography identifies SAH-related preretinal and vitreous hemorrhages with high accuracy and is superior to standard head CT. It may be considered as new and useful bedside diagnostic tool for routine clinical care of patients with SAH.

Keywords: SAH-related ocular hemorrhage (OH); Terson's syndrome; head computed tomography (CT); ocular sonography; subarachnoid hemorrhage (SAH).

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Eye Hemorrhage / diagnostic imaging*
  • Eye Hemorrhage / etiology
  • Female
  • Humans
  • Male
  • Middle Aged
  • Ophthalmoscopy
  • Sensitivity and Specificity
  • Subarachnoid Hemorrhage / complications
  • Subarachnoid Hemorrhage / diagnostic imaging*
  • Tomography, X-Ray Computed*
  • Ultrasonography*