Purpose: To determine whether haptic flanging during 27-gauge sutureless intrascleral fixation of intraocular lenses (IOLs) increases IOL stability and to report the short-term clinical outcomes of sutureless intrascleral surgery using 27-gauge trocar cannulas with haptic flanging.
Methods: Retrospective surgical case series using live and cadaveric human eyes.
Results: In the cadaveric experiment using five eyes, flanged haptics required more force to dislocate the IOL compared with unflanged haptics (14 ± 4 vs. 3 ± 1 g, P = 0.03). The clinical series included 52 eyes from 52 patients. The average age at the time of surgery was 73 ± 14 years, with a mean follow-up of 27 ± 19 weeks. The most common indication for surgery was IOL dislocation/subluxation (n = 43, 83%). Mean visual acuity improved from 20/140 preoperatively to 20/50 at postoperative Month 1 (P < 0.001). The most common postoperative issue was intraocular pressure elevation (n = 12, 23%). Two patients (4%) needed a reoperation for IOL dislocation.
Conclusion: Haptic flanging during 27-gauge sutureless intrascleral surgery creates a more stable scleral-fixated IOL compared with the traditional unflanged technique based on a cadaveric human eye study. In addition, this variation of sutureless intrascleral surgery seems safe and effective for patients who require secondary IOLs.