Refractive Outcomes of Four-Point Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture

Clin Ophthalmol. 2020 Dec 21:14:4431-4437. doi: 10.2147/OPTH.S282094. eCollection 2020.

Abstract

Background/objective: To determine the refractive outcomes after 4-point scleral fixation of the Akreos AO60 intraocular lens with Gore-Tex suture.

Methods: This was a single referral center, multi-surgeon, retrospective consecutive case series. A total of 63 eyes met the inclusion criteria for having received surgical implantation of the Akreos AO60 intraocular lens with Gore-Tex suture from August 2014 to December 2018. Exclusion criteria included all ocular pathology that precluded an accurate refraction, concurrent ocular surgery, poor corrected pre-operative visual potential, among other factors. Main outcome measures included post-operative uncorrected visual acuity (VA), best-corrected VA, and spherical equivalent deviation from target.

Results: Mean pre-operative BCVA was 0.67 ± 0.64 LogMAR (20/93 Snellen). Mean final post-operative BCVA was 0.17 ± 0.18 (20/28 Snellen) and mean final post-operative UCVA was 0.31 ± 0.22 (20/41 Snellen). Mean post-operative spherical equivalent was -0.57 D. Mean post-operative astigmatism was 0.85 D.

Conclusion: Refractive outcomes after secondary implantation with Akreos AO60 are favorable in eyes with good visual potential.

Keywords: Akreos AO60 lens; Gore-Tex; refractive outcomes secondary intraocular lens; scleral fixated IOL.