Hemoglobin desaturation during sleep and daytime in patients with cystic fibrosis and severe airway obstruction

Acta Paediatr. 1992 Dec;81(12):1002-6. doi: 10.1111/j.1651-2227.1992.tb12163.x.

Abstract

Transcutaneous hemoglobin saturation by pulse oximetry was evaluated during sleep and for 2-3 h during the day in 31 patients with cystic fibrosis (median age 15.2 years; range 7.6-33.6 years) and severe airway obstruction. Pulse oximetry readings were analyzed as a cumulative percentage of time in which oxygen saturation was < 90% during both sleep and daytime. Each patient was also examined using clinical and radiological scores, spirometry and arterial blood-gas analysis. The agreement between arterial and transcutaneous saturation was evaluated in 29 patients. The difference between transcutaneous and arterial saturation was 2.4 +/- 2.0% and it increased as arterial saturation decreased. Clinical and radiological scores and spirometry parameters showed a poor correlation with both overnight and daytime desaturation. An arterial saturation < 94% may indicate a risk of consistent desaturation. This occurred for more than 50% of the time in 11 of 20 patients during sleep and in 5 of 20 patients during daytime hours.

MeSH terms

  • Adolescent
  • Adult
  • Airway Obstruction / blood*
  • Blood Gas Monitoring, Transcutaneous
  • Child
  • Cystic Fibrosis / blood*
  • Female
  • Hemoglobins / analysis*
  • Humans
  • Male
  • Oximetry
  • Oxygen / blood*
  • Sleep / physiology*

Substances

  • Hemoglobins
  • Oxygen