Impact of carbon coating on the restenosis rate after stenting of atherosclerotic renal artery stenosis

J Endovasc Ther. 2005 Oct;12(5):605-11. doi: 10.1583/05-1599MR.1.

Abstract

Purpose: To investigate the impact of carbofilm coating and low-profile rapid exchange stent devices on the restenosis rate after stent-angioplasty of atherosclerotic renal artery stenosis (RAS).

Methods: During a 2-year period (7/2002-7/2004), 143 consecutive patients with 179 primary ostial atherosclerotic RAS>or=70% diameter stenosis were treated with stents selected at the discretion of the operator. Eighteen patients (32 lesions) treated with 9 different types of stents were excluded from the analysis, leaving 125 patients (69 men; mean age 67 years, range 42 to 90) with 147 lesions who received either a Radix carbofilm-coated stent in 78 (53%) lesions (68 [54%] patients) or a Palmaz Genesis bare stainless steel stent in 69 (47%) lesions (57 [46%] patients). The target vessel diameter ranged from 5 to 7 mm.

Results: Baseline characteristics were similar in both groups except the mean stent diameter, which was larger in the bare stent cohort (6.4+/-0.7 versus 5.9+/-0.5 mm, p<0.001). Primary success was 100% in both groups; the initial mean diameter stenosis was reduced from 79%+/-14% and 80%+/-14% in the coated versus bare stent groups to 3+/-5% and 2+/-6%, respectively. After a mean follow-up of 22+/-5 months, the restenosis rate was 6.4% for the coated stent and 5.8% for the bare stent (p=0.87). For the entire cohort, restenosis rates varied significantly (p<0.05) according to stent diameter: 19% (5/26) for 5 mm, 4% (3/81) for 6 mm, and 2.5% (1/40) for 7 mm. In a binary logistic regression analysis including carbofilm coating, stent diameter, gender, diabetes, smoking status, and body mass index, stent diameter was the only independent predictor of restenosis (odds ratio 0.12, 95% CI 0.03 to 0.48 [p=0.003] for a 1-mm increase in vessel diameter).

Conclusions: Using modern low-profile stent devices, carbofilm coating does not significantly reduce the restenosis rate compared to a bare metal stent. With contemporary stent devices, the restenosis rate has been decreasing compared to earlier reports in the literature.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Atherosclerosis / diagnostic imaging
  • Atherosclerosis / therapy*
  • Blood Vessel Prosthesis Implantation
  • Carbon / therapeutic use*
  • Coated Materials, Biocompatible / therapeutic use*
  • Female
  • Follow-Up Studies
  • Graft Occlusion, Vascular / diagnostic imaging
  • Graft Occlusion, Vascular / etiology*
  • Humans
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Postoperative Complications / diagnostic imaging
  • Postoperative Complications / etiology
  • Renal Artery Obstruction / diagnostic imaging
  • Renal Artery Obstruction / therapy*
  • Stents*
  • Treatment Outcome
  • Ultrasonography, Doppler, Color

Substances

  • Coated Materials, Biocompatible
  • Carbon