Comparison of the anaesthetic requirement with target-controlled infusion of propofol to insert the laryngeal tube vs. the laryngeal mask

Eur J Anaesthesiol. 2005 Nov;22(11):858-63. doi: 10.1017/S0265021505001456.

Abstract

Background and objective: The target effect-site concentration of propofol to insert a laryngeal mask airway was recently reported as almost 5 microg mL(-1). The present study aimed to determine the target effect-site concentration with target-controlled infusion of propofol to place classical larnygeal mask airway or current laryngeal tube in adult patients.

Methods: We included 40 patients scheduled for short gynaecological and radiological procedures under general anaesthesia in a randomized, double-blind manner using the Dixon's up-and-down statistical method. Monitoring included standard cardiorespiratory monitors, and bispectral index monitoring was used for all patients. Anaesthesia was conducted with a target-controlled infusion system: Diprifusor. The initial target plasma concentration of propofol was 5 microg mL(-1), and was changed stepwise by 0.5 microg mL(-1) increments according to Dixon's up-and-down method. Criteria for acceptable insertion were: Muzi's score < or = 2, and mean arterial blood pressure, heart rate or bispectral index variation <20% the baseline values.

Results: Target effect-site concentration of propofol required to insert laryngeal tube was 6.3 +/- 0.3 microg mL(-1) with Dixon method and ED50 was 6.1 microg mL(-1) (5.9-6.4) with logistic regression method. In the case of larnygeal mask airway they were 7.3 +/- 0.2 microg mL(-1) (Dixon method) and 7.3 microg mL(-1) (7.1-7.5; with logistic regression) respectively (P < 0.05). ED95 (logistic regression) was 6.8 microg mL(-1) (5.9-7.6) for laryngeal tube and 7.7 microg mL(-1) (7.3-8.0) for larnygeal mask airway (P < 0.05). Haemodynamic incidents were 55% in the larnygeal mask airway group vs. 30% in the laryngeal tube group (P < 0.05).

Conclusions: The target effect-site concentration of propofol for insertion of laryngeal tube was lower than for larnygeal mask airway (P < 0.05), with a consequent reduction of the propofol induced haemodynamic side-effects.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Anesthesia, Intravenous / methods*
  • Anesthetics, Intravenous / administration & dosage*
  • Anesthetics, Intravenous / adverse effects
  • Dose-Response Relationship, Drug
  • Double-Blind Method
  • Female
  • Hemodynamics / drug effects
  • Humans
  • Infusions, Intravenous
  • Intubation, Intratracheal*
  • Laryngeal Masks*
  • Logistic Models
  • Male
  • Middle Aged
  • Propofol / administration & dosage*
  • Propofol / adverse effects

Substances

  • Anesthetics, Intravenous
  • Propofol