Negative pressure suction technique for bone cement introduction into the delivery syringe. A technical note

Acta Orthop Belg. 2009 Aug;75(4):543-5.

Abstract

The authors present in this brief note a technique to facilitate the introduction of high viscosity bone cement into a cement syringe for retrograde high pressure cementing during total hip or revision knee arthroplasty. The nozzle part of the syringe is connected to the suction device used intra-operatively, to achieve a negative pressure in the syringe. Introduction of the cement into the syringe is thus greatly facilitated, which saves time during the curing process.

MeSH terms

  • Arthroplasty, Replacement, Hip
  • Arthroplasty, Replacement, Knee
  • Bone Cements*
  • Cementation / methods*
  • Drug Delivery Systems*
  • Humans
  • Reoperation
  • Suction / methods*
  • Syringes

Substances

  • Bone Cements