Comparison of acoustic radiation force impulse imaging (ARFI) to liver biopsy histologic scores in the evaluation of chronic liver disease: A pilot study

Ann Hepatol. 2010 Jul-Sep;9(3):289-93.

Abstract

Background and aims: Acoustic Radiation Force Impulse Imaging (ARFI) is a novel non invasive technique studying the localized mechanical properties of tissue by utilising short, high intensity acoustic pulses (shear wave pulses) to assess the mechanical response (tissue displacement), providing a measure of tissue elasticity. The aim of this study is to investigate the feasibility of ARFI imaging as a non-invasive method for the assessment of liver fibrosis compared to liver biopsy scores.

Materials and methods: A prospective blind comparison study of ARFI elastography (Virtual Touch Imaging., ACUSON S2000 Ultrasound Unit, Siemens, Mountain View CA) in a consecutive series of patients who underwent liver biopsy for assessment of fibrosis in chronic liver disease. ARFI shear-wave propagation velocity was measured in meters per second. Mean ARFI velocities were compared with both Batts-Ludwig (F0 to F4) and Modified Ishak scores (F0 to F4) for fibrosis in liver biopsy findings. Twenty-one patients with chronic liver disease (Hepatitis C (HCV) =16, Hepatitis B (HBV) = 1, both HCV and HBV = 1 Alcoholic liver disease (ALD) = 1, others = 2) underwent ARFI and liver biopsy on the same day.

Results: The Spearman correlation coefficients between the median values of the ARFI measurements and the histological fibrosis stage of the Modified Ishak score and Batts-Lud- (3) wig score were both highly significant (p < 0.01) with rho = 0.69 and rho = 0.72 respectively. The median ARFI (total 180 replications; minimum 5, maximum 10 measurements per patients) velocities for our study population range from 0.92 to 4.17 m/sec. Areas under the receiver operating characteristic curve for the accuracy of ARFI imaging was 1.00 and 0.35, for the diagnosis of moderate fibrosis (histologic fibrosis stage, F (3) 2) and 0.85 and 0.85 respectively for Ishak and Batts-Ludwig score, for the diagnosis of cirrhosis.

Conclusion: ARFI imaging has a strong correlation with the fibrosis stage of both Batts-Ludwig and shak score in chronic liver disease. It.s accuracy in prediction of severe fibrosis and cirrhosis is maximal in comparison with earlier stages.

Publication types

  • Comparative Study
  • Validation Study

MeSH terms

  • Biopsy / methods
  • Biopsy / standards*
  • Chronic Disease
  • Elasticity Imaging Techniques / methods
  • Elasticity Imaging Techniques / standards*
  • Hepatitis B, Chronic / diagnostic imaging
  • Hepatitis B, Chronic / pathology
  • Hepatitis C, Chronic / diagnostic imaging
  • Hepatitis C, Chronic / pathology
  • Humans
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Cirrhosis / diagnostic imaging
  • Liver Cirrhosis / pathology
  • Liver Diseases / diagnostic imaging*
  • Liver Diseases / pathology*
  • Liver Diseases, Alcoholic / diagnostic imaging
  • Liver Diseases, Alcoholic / pathology
  • Pilot Projects
  • Predictive Value of Tests
  • Reference Standards
  • Reproducibility of Results