Cardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy)

J Am Coll Cardiol. 2011 Oct 11;58(16):1682-9. doi: 10.1016/j.jacc.2011.07.020.

Abstract

Objectives: We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT).

Background: There is limited information regarding the effect of CRT-D on the risk of AT.

Methods: Percent reduction in LAV at 1 year following CRT-D implantation (pre-specified as low [lowest quartile: <20% reduction in LAV] and high [≥20% reduction in LAV] response to CRT-D) were related to the risk of subsequent AT (comprising atrial fibrillation, atrial flutter, atrial tachycardia, and supraventricular tachyarrhythmias) among patients enrolled in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

Results: The cumulative probability of AT 2.5 years after assessment of echocardiographic response was lowest among high LAV responders to CRT-D (3%) and significantly higher among both low LAV responders to CRT-D (9%) and implantable cardioverter-defibrillator-only patients (7%; p = 0.03 for the difference among the 3 groups). Consistently, multivariate analysis showed that high LAV responders to CRT-D experienced a significant 53% (p = 0.01) reduction in the risk of subsequent AT as compared with implantable cardioverter-defibrillator-only patients, whereas low LAV responders did not derive a significant risk reduction with CRT-D therapy (hazard ratio [HR]: 1.05 [95% confidence interval (CI): 0.54 to 2.00]; p = 0.89). Patients who developed in-trial AT experienced significant increases in the risk for both the combined endpoint of heart failure or death (HR: 2.28 [95% CI: 1.45 to 3.59]; p < 0.001) and the separate occurrence of all-cause mortality (HR: 1.89 [95% CI: 1.08 to 3.62]; p = 0.01).

Conclusions: In the MADIT-CRT study, favorable reverse remodeling of the left atrium with CRT-D therapy was associated with a significant reduction in risk of subsequent AT. (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cardiac Resynchronization Therapy / methods*
  • Defibrillators, Implantable*
  • Echocardiography / methods
  • Female
  • Heart Atria / pathology
  • Heart Failure / therapy*
  • Humans
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Proportional Hazards Models
  • Risk
  • Tachycardia / therapy*

Associated data

  • ClinicalTrials.gov/NCT00180271