Diagnostic performance of fluorine-18-fluorodeoxyglucose positron emission tomography in the assessment of pleural abnormalities in cancer patients: a systematic review and a meta-analysis

Lung Cancer. 2014 Jan;83(1):1-7. doi: 10.1016/j.lungcan.2013.11.002. Epub 2013 Nov 13.

Abstract

Objective: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients.

Methods: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out.

Results: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found.

Conclusions: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.

Keywords: (18)F-FDG; Lung cancer; PET/CT; Pleura; Pleural effusion; Positron emission tomography.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Animals
  • Diagnostic Errors
  • Fluorodeoxyglucose F18*
  • Humans
  • Lung Neoplasms / diagnosis*
  • Lung Neoplasms / pathology
  • Multimodal Imaging
  • Pleura / diagnostic imaging*
  • Pleura / pathology
  • Pleural Neoplasms / diagnosis*
  • Pleural Neoplasms / pathology
  • Positron-Emission Tomography / methods*
  • Sensitivity and Specificity

Substances

  • Fluorodeoxyglucose F18