LC-MS/MS determination of apixaban (BMS-562247) and its major metabolite in human plasma: an application of polarity switching and monolithic HPLC column

Bioanalysis. 2014 Aug;6(15):2071-82. doi: 10.4155/bio.14.66.

Abstract

Background: apixaban (BMS-562247) (Eliquis(®)) is a novel, orally active, selective, direct, reversible inhibitor of the coagulation factor Xa (FXa). A sensitive and reliable method was developed and validated for the measurement of apixaban (BMS-562247) and its major circulating metabolite (BMS-730823) in human citrated plasma for use in clinical testing.

Methodology/results: A 0.100 ml portion of citrated plasma sample was extracted and analyzed by LC-MS/MS. Run times were approximately 3 min. The lower limit of quantification (LLOQ) was 1.00 ng/ml for BMS-562247 and 5.00 ng/ml for BMS-730823. Intra- and inter-assay precision values for replicate QC control samples were within ≤5.36% for both analytes (≤7.52% at the LLOQ). The accuracy for both analytes was within ±9.00%.

Conclusion: The method was demonstrated to be sensitive, selective and robust, and was successfully used to support clinical studies.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, High Pressure Liquid / instrumentation
  • Chromatography, High Pressure Liquid / methods*
  • Factor Xa Inhibitors / blood
  • Humans
  • Pyrazoles / blood*
  • Pyridones / blood*
  • Tandem Mass Spectrometry / methods*

Substances

  • Factor Xa Inhibitors
  • Pyrazoles
  • Pyridones
  • apixaban